The fuel intake of the yacht is equipped with a flow switch having the function to prevent undesired leaks of fuel from the plug an d from the vent which may stain the bridge and pollute the water. The leak of fuel may occur during refuelling, if the tanks are almost completely full.
The fuel coming out of the intake duct is collected in a tank with suitable capacity, which, on its turn, will drain automatically into the fuel tank, through the return duct.
Also the flow switch is equipped with own air vent, bleeding from the wall near the filler plug of the tank.
The inlet plug carries the indication “DIESEL” to avoid accidental input of different fuels.
Filling lines pressure must be kept constantly under 0.3bar during bunkering operations.
Before refuelling, wash the teak with fresh water to avoid its contamination with fuel.
During refuelling operations, do not approach open flames to the yacht; do not smoke. Carry out refuelling with engine shut off. The lack of consideration of these precautions can cause accidents and injuries.