7.1.3 Stop of propulsion engines
Do not immediately stop the engines after a full-load operation, but let them run low (about 5 minutes) to balance the temperature differences.
- Bring the levers back to the central neutral position on the inverter.
- Press the STOP buttons on the engine control panels and release them only after the engines have come to a complete stop.
- Press the IGNITION buttons. The signal LED will switch OFF.
- Disconnect unnecessary magneto-thermal switches.
CAUTION
With engines stopped carry out following:
- Disconnect all unnecessary electric utilities and check the general status of the switchboard as well as the voltmeters and ammeters indications;
- Check the switches of the bilge pumps and their regular operation;
- Check for leaks;
- Rinse the yacht with fresh water;
- Connect the shore electric power supply;
- Keep the engine room extractor running for about 30 minutes, for ventilation and air cooling.
DANGER
Make sure that the engines cannot be started by unauthorized staff.