14.7 INVERTER

For further information, please contact the RIVA Service Department.


AFTER-SALES SERVICE BROCHURE


Problem Cause Corrective action
1. No output voltage and no lighting of warning lights (LED off) High output voltage Check the battery voltage and switch off the charger
DC fuse burnt out Replace the fuse
Switch set on remote control, but this is not available Place the switch to ON
2. No voltage in output, LED of battery charge is ON Batteries flat Charge the batteries, the inverter will switch on when the battery voltage exceeds 24 V
3. No voltage in output, temperature LED in ON The inverter is overloaded Reduce the charge and let the inverter cool down
4. No output voltage, LED “ON” is lit Inverter is in stand-by Connect a charge or modify the jumper’s settings
5. Low voltage in output Low power supply = jumper adjustment Connect a charge > 30 W or modify the jumper’s settings
6. The inverter turns on and off, the “ON” LED and the battery charger LED flash in turns Batteries flat Disconnect the charge and charge the batteries
Wires are too thin Replace with wires of correct diameter
The connections are corroded or faulty Tighten connections. If wires are burnt out, replace them
7. The inverter lights ON/OFF, the ON LED is lit, the “overload” LED flashes once a second and the fan operates at full speed. The inverter is overloaded Reduce the inverter load
The inverter has been switched off ten times as a result of an overload or short- circuit condition Reduce the load or the short-circuit. Reset the inverter manually through ON/OFF switch