14.5 GENERATORS

For further information, please contact the RIVA Service Department.


AFTER-SALES SERVICE BROCHURE


Problem Cause Corrective action
1. Fluctuating or low oil pressure Oil level too low Stop the generator immediately and top up with suitable oil
Dirty oil Replace dirty oil with new suitable oil
2. Cooling water temperature too high Excessive load Reduce the load
Air in the cooling circuit Bleed the circuit
Coolant low level or wrong mixture Restore the cooling water level and correct percentage
Sea water intake is obstructed or sea water intake strainer is clogged Clean sea cock and strainer
3. Black smoke Engine room insufficient ventilation Check that air intakes are not obstructed
Excessive load
Reduce the load
Unsuitable fuel Replace with suitable fuel
Cooling water temperature too high See step 2
Lack of maintenance Have the scheduled maintenance operations carried out
4. Blue smoke Excessive oil Discharge the excess oil by draining oil filters
Dirty oil Replace dirty oil with new suitable oil
Lack of maintenance Have the scheduled maintenance operations carried out
5. White smoke Cold generator Let the generator warm up
Generator with too low load Increase the generator load
6. Lack of power Engine room insufficient ventilation Check that air intakes are not obstructed
Fuel filter clogged Clean
Unsuitable fuel Replace with suitable fuel
Cooling water temperature too high See step 2
Lack of maintenance Have the scheduled maintenance operations carried out
7. Excessive or unusual noise Insulation cover not properly fastened Check
Leakage from the exhaust Check the exhaust
Exhaust not properly fastened Check the exhaust
Lack of maintenance Have the scheduled maintenance operations carried out