| Component | Maintenance | Notes and precautions |
| Equipment and circuits | Cleaning and checks | At least once every six months, have the various connections of electric boards, panels and boxes checked by experienced personnel. Make sure that ground connections of electrical equipment and electric panels are tight and not oxidized. Have the absorption of the different electric motors periodically checked by skilled personnel. When cleaning the bottom hull, carefully clean the electronic instrument ground static discharger and the porous plate connected the power generator grounding. Moreover, check the condition of the protection anodes and if necessary, replace them. During the lay-up period, do not apply any antifouling on the ground static dischargers. |
At least once a week check the operation of all electrical panels.
At least once every six months:
Do not modify the electric systems or relevant drawings. The installation, the modifications or the maintenance must be carried out only by a skilled naval electrician. Inspect the system at least once a year.
Before carrying out any intervention on the electric system, disconnect all circuits (shore, generators and inverter):
It is forbidden to use pressurized water on light appliances installed outside.