Operation check
Before each intervention make sure that voltage is disconnected and that there is no possibility of accidental connection.
Check that the pump shaft turns freely (this is possible by inserting the screwdriver in the back end of the engine shaft).
Check the rotation direction, that the pump motor works within its output range and that the absorbed current is not higher than the one indicated in the tag.
These pumps, normally, do not need ordinary maintenance, provided that some measures are taken which extend their operation.
Bilge pump operation check
Never run the electric pumps dry.
Check the operation of all bilge pumps at regular intervals. Clean debris from pump inlets.
Non-return valves”
The on-board hydraulic system consists of check valves (or non-return valves) “EUROPE” type (1) and “CLAPET” type (2).
They require extraordinary maintenance only,due to their lack of operation, which can be caused by a foreign body inside the valve itself, or by a mechanical break; in both cases, check the failure, if it is not removable, carry out the replacement.