| Component | Maintenance | Notes and precautions |
| Fresh water tanks | Cleaning and checks | At least every month, drain the fresh water tanks completely and rinse them a couple of times with clean fresh water for change completely the water stowed in the storing tanks and at the same time to wash them too. Periodically pour a specific disinfectant, in the quantity recommended by the Builder, into the tanks, through the intake filler, in order to prevent the formation of bacteria in the system. |
| Electric water heater | Cleaning and checks | MAINTENANCE
At least once a month check the operation of the water heater. If warm water is not available, because of the fresh water circuit discharge, switch off the water heater to prevent damaging it resistor. |
| Fresh water system | Checks | In case of need or of maintenance, by acting on the valves installed on the distribution manifolds, it is possible to cut out parts of the system or single utilities, without involving the operation of the general system. Check if along the hydraulic circuit, where possible, are present leaks due to the damage of piping. The high temperature can cause the softening of the pipes and the following slackening of the fittings. Always check the pipes tightening, especially those located near heat sources. During the winter, if you do not use the yacht, it is advisable to drain all the circuits where there is fresh water to avoid cracks due to frost. |
| Surge tank pump | Cleaning and checks | The maintenance of the pump should be serviced by qualified personnel only, after having been disconnected from the power mains. No routine maintenance is required so long as the following precautions are taken:
Protect electric components of the pump with proper products. NOTE
For further information on use and maintenance, please refer to the manufacturer’s manual. During the winter, if you do not use the yacht, it is advisable to drain all the circuits where there is fresh water to avoid cracks due to frost. The surge tank pump is self-priming but it needs though, in order to operate, to have its body filled with liquid. If the control panel shows the pump operating led remains always lit, but the connected utilities are not in use, check for leaks. When anomalous situations occur, such as lack of water or pipes clogging, it indicates the presence of faults by means of the red light “Failure” and stops the pump. Before carrying out maintenance on the fresh water pump, avoid its accidental priming. |