Smoke detection control unit
The alarm devices include a smoke detection unit (1), a flashing signal unit (2). These devices are activated in the event of smoke detected by sensors positioned in the engine room, and other areas of the yacht.
You can monitor the presence of smoke in the yacht also from the panel touch screen present on the dashboard.
At least every month carry out an operation test.
Bilge water alarm system
An alarm siren (3) is provided to warn against a high water level in the bilge, operated by floating switches located in the various compartments of the bilge on board.
The alarm is on the monitoring system in the main and fly helm stations by means of an acoustic light/signal.
At least once a week check the operation of the floating switches and of the siren.
At least once a month clean the floating switches.
To prevent false alarms, make sure that the system is isolated and disabled before performing maintenance and cleaning of the smoke detectors. Once the periodic maintenance of all detectors in food and rehabilitate the system.
For further information on use and maintenance, please refer to the manufacturer’s manual.