6.9 INVERTER (OPT)

The inverter is a completely automatic high-efficiency device.
The inverter transforms the 24V DC voltage into 230 V AC.

  • ON, Switch
    Position the ON/OFF switch, located on the front panel of the inverter to “ON”. The green light “inverter on” lights up and the inverter starts.
  • OFF, Switch
    Position the ON/OFF switch, located on the front panel of the inverter to “OFF”. The inverter stops and all lit lights switch off.
  • Warning lights
    The functions of the warning lights located on the inverter front panel are:

    DANGER

    When disconnecting the inverter by means of the switch located on the front panel the connection with the mains is not broken OFF.

    DANGER

    Do not work on the inverter or on its system if still connected to a current supply. Only qualified staff can carry out interventions on the electric system and only after the approval of RIVA.

    DANGER

    Have the inner condition of the inverter checked at least once a year by skilled personnel. Faults like loose connections, burnt wires, etc.., with following fire break risks, must be removed immediately.

    WARNING

    The uses supplied by the inverter highly stress the batteries that could discharge as a result.

    MAINTENANCE

    At least once a month check the correct operation of the inverter.
    At least once a month carry out the complete cleaning.
    At least once every six months protect the contacts with proper products.

    NOTE

    For further information on use and maintenance, please refer to the manufacturer’s manual.

    INVERTER USERS MANUAL