The yacht is equipped with a multi-purpose pump (1) 165 l/min, which can be used, in case of emergency, to help or to replace the various automatic bilge pumps, in order to drain water from the bilge.
In addition to the pump, the system consists of suction units located in the various areas of the yacht.
One of these suctions (2) is located inside the stabiliser fin compartment. To carry out the suction, it is necessary to act on the three-way valve (3) present in the bilge opposite the entrance to the VIP bathrooms.
The multi- purpose pump, activated manually, by correctly shunting the valves on the relevant manifold, can replace the following pumps:
In case of failure of black or grey water pumps, the multi-purpose pump replaces the suction of one of the two pumps, by means of two deflecting valves installed on the multi-purpose pump manifold.
After the use of the multi-purpose pump, it is advisable to carry out a check of the impeller. For the procedure ask the CUSTOM LINE After Sales & Service Department.
To use the multi-purpose pump, activate the magneto-thermal switch located on the general electrical panel.
The bilge drains can be discharged at sea only if they do not contain polluting substances.
If polluting agents are present in the bilge waters, dispose of them using the suitable containers for polluting agents located in harbours.
Never run the electric pumps dry.